AirSprayTech Academy Certificate Program
Water and Wastewater Protective Coating Systems | Article 10 of 24
Repairing Concrete, Rebuilding Surfaces, and Correcting Deterioration
A protective lining cannot restore missing concrete, replace structural capacity, or correct active deterioration. The substrate must first be evaluated, repaired, and rebuilt into a sound surface capable of supporting the specified system.
Coatings Protect Concrete; They Do Not Reconstruct It
Concrete in water and wastewater facilities may be weakened by chemical attack, reinforcement corrosion, erosion, abrasion, freeze-thaw damage, cracking, leakage, poor consolidation, or long-term exposure to moisture and treatment chemicals.
Applying a high-build coating over unsound concrete does not correct the underlying condition. The lining may remain attached to a thin surface layer while that layer separates from the concrete beneath it. The apparent coating failure is then actually a substrate failure.
Structural Repairs Require Qualified Design
Coating contractors should recognize concrete deterioration, document what they find, and perform repairs that are within their qualifications and contractual responsibility. They should not independently design structural repairs, remove critical concrete, cut reinforcing steel, or change the configuration of a structure unless the work is supported by approved repair documents.
When deterioration affects structural capacity, reinforcing steel, wall thickness, liquid containment, joints, foundations, or load-bearing components, the owner should obtain direction from a licensed design professional experienced in concrete assessment and repair.
Determine Why the Concrete Deteriorated
A repair should address the cause of deterioration, not merely fill the visible cavity. Before selecting a repair material, determine the exposure, moisture condition, depth of damage, structural significance, and probable deterioration mechanism.
- Biogenic sulfuric-acid attack in wastewater headspaces
- Chemical attack from acids, alkalis, disinfectants, or industrial discharge
- Corrosion of embedded reinforcing steel
- Carbonation or chloride intrusion
- Erosion, abrasion, cavitation, or high-velocity flow
- Freeze-thaw exposure and saturation
- Cracking caused by movement, shrinkage, settlement, or overload
- Leakage through cracks, joints, penetrations, or failed waterstops
- Honeycombing, voids, fins, form offsets, and poor consolidation
- Previous repairs that are incompatible, poorly bonded, or deteriorated
Define the Repair Area
Visible damage does not always show the full extent of unsound concrete. Delamination may extend beyond a spall, and chemically weakened concrete may remain in place even though the surface appears solid.
Investigation may include:
- Visual examination under adequate lighting
- Hammer sounding or chain dragging where appropriate
- Probing cracks, voids, and deteriorated areas
- Measuring the depth and area of material loss
- Locating reinforcing steel, utilities, conduits, and embedded components
- Measuring pH or evaluating chemical attack when specified
- Bond, tensile, compressive, or other testing directed by the project documents
- Engineering evaluation when structural deterioration is suspected
Removal Can Affect Structural Stability
Removing deteriorated concrete changes the section of the structure and can reduce support around reinforcing steel. Overhead work, deep removals, large repair areas, thin walls, prestressed components, and repairs around heavily corroded reinforcement may require engineered sequencing, temporary shoring, or other controls.
Before demolition begins, confirm the permitted removal limits, work sequence, structural restrictions, utility locations, containment requirements, and stopping conditions.
Remove All Unsound Concrete
Deteriorated concrete should be removed to the limits required by the repair documents. The remaining concrete must be sound enough to support the repair material and the protective coating or lining.
Removal methods may include:
- Chipping with properly sized pneumatic or electric tools
- Scarifying, grinding, milling, or scabbling
- Abrasive blasting
- Hydrodemolition or high-pressure water removal
- Saw cutting used carefully to establish repair boundaries when specified
Aggressive impact tools can bruise or microcrack the concrete left behind. The selected method should remove the damaged material without unnecessarily weakening the repair substrate, damaging reinforcement, or cutting embedded utilities.
Establish Sound Repair Boundaries
Repairs should not taper to a feather edge unless the approved repair material is specifically designed for that application. Thin, unsupported edges can dry too quickly, crack, debond, or break under service conditions.
Repair boundaries should follow the project detail and provide the minimum depth required by the repair-material manufacturer. Saw cuts must not damage reinforcing steel, waterstops, embedded electrical components, post-tensioning systems, or other concealed items.
Treat Exposed Reinforcing Steel Correctly
Corroding reinforcement expands and can crack or delaminate the surrounding concrete. If steel is exposed during removal, the repair documents should define the required clearance, cleaning, evaluation, replacement, supplemental reinforcement, and corrosion treatment.
- Remove loose rust, scale, concrete residue, and bond-inhibiting contamination as specified.
- Clean the back side of reinforcement when the repair detail requires complete exposure.
- Report significant section loss, broken bars, damaged welds, or displaced reinforcement.
- Do not cut, heat, bend, weld, or replace reinforcement without authorization.
- Apply reinforcing-steel primers, corrosion inhibitors, or protective treatments only when specified and compatible with the repair system.
Select Repair Materials for the Exposure
The repair material becomes part of the lining substrate. It must be suitable for the repair geometry, placement method, environmental conditions, cure schedule, chemical exposure, moisture condition, and protective system that will be applied over it.
Important selection properties include:
- Bond to the prepared concrete
- Compressive, tensile, and flexural properties
- Modulus of elasticity and compatibility with the existing concrete
- Shrinkage and dimensional stability
- Required placement thickness and orientation
- Vertical, overhead, formed, pumped, troweled, or sprayed application capability
- Resistance to moisture, immersion, chemicals, abrasion, and thermal movement
- Cure time and permitted time before coating
- Moisture and surface-conditioning requirements
- Compatibility with the primer, resurfacer, coating, or lining system
Common Categories of Repair Material
Cementitious Repair Mortars
Portland-cement and polymer-modified cementitious mortars are commonly used to replace deteriorated concrete and restore profile. They may require a saturated-surface-dry substrate, bonding treatment, moist curing, or a prescribed curing period before coating.
Calcium-Aluminate and Specialty Cementitious Materials
Specialty cementitious materials may be selected for rapid return to service or improved resistance in wastewater environments. Their use must follow the approved system design, because resistance varies with formulation and exposure.
Epoxy and Polymer Repair Materials
Epoxy mortars and other polymer materials can provide rapid strength, strong adhesion, and chemical resistance. Their thermal movement, moisture sensitivity, placement limits, exotherm, and compatibility with damp concrete must be considered.
Resurfacers and Underlayments
Cementitious or resinous resurfacers can fill widespread surface irregularities and establish a uniform substrate for the lining. A resurfacer should not be used to conceal active movement, unsound concrete, uncontrolled leakage, or structural deficiencies.
Prepare the Repair Substrate
The concrete receiving the repair must be sound, clean, and properly profiled. Dust, laitance, oil, grease, biological residue, chemicals, loose aggregate, and weakened concrete interfere with bond.
Surface profile and moisture condition should comply with the approved repair-material instructions. Some cementitious materials require a saturated-surface-dry condition. Some resinous products require dry concrete. These conditions are not interchangeable, and assumptions should not replace the manufacturer’s written instructions.
Mixing and Placement Control
Repair materials are engineered products. Changing the liquid ratio, adding unauthorized water, extending pot life, or mixing partial units incorrectly can change strength, shrinkage, permeability, cure, and bond.
- Confirm product identity, batch numbers, shelf life, and storage condition.
- Condition materials within the specified temperature range.
- Use clean mixing equipment and the required mixer type.
- Measure liquid accurately and mix for the specified time.
- Observe working time, placement thickness, lift limitations, and recoat intervals.
- Consolidate the material around reinforcement and into irregularities.
- Do not place material that has begun to stiffen beyond its permitted working time.
- Make test batches or field mockups when required.
Rebuild the Correct Geometry
Repair work should restore more than the approximate shape of the structure. The completed surface must provide the geometry needed for drainage, cleaning, lining continuity, inspection, and service.
- Restore slopes toward drains and prevent unintended ponding.
- Fill honeycombing, bugholes, voids, offsets, and abrupt irregularities.
- Rebuild deteriorated wall bases, channels, benches, curbs, and equipment pads.
- Form smooth transitions at penetrations, pipe entries, and embedded components.
- Provide specified coves or fillets at inside corners.
- Round or ease outside edges when required by the lining system.
- Preserve designed movement joints instead of filling them rigidly without authorization.
Finish for the Lining, Not for Appearance Alone
A slick, steel-troweled repair may look attractive but provide inadequate profile for a bonded lining. A rough repair may trap air, create pinholes, produce excessive coating consumption, or prevent holiday-free coverage.
The required finish should be coordinated among the repair-material manufacturer, coating manufacturer, specification, and inspector. After curing, additional mechanical preparation may be required to remove laitance, expose sound material, and create the specified surface profile.
Cure and Protect the Repair
Repair materials need the specified temperature, moisture condition, and curing time to develop their intended properties. Premature drying, freezing, excessive heat, immersion, vibration, contamination, or early coating can damage the repair.
Membrane-forming curing compounds can interfere with coating adhesion unless expressly approved. If a curing compound is used, confirm its compatibility or the method required for its complete removal before the lining is applied.
Control Water Before Making the Repair
Running water, active leakage, and negative-side moisture can wash out cement, dilute resin, prevent bond, create voids, or cause uncured material to move. Active leaks must be controlled by an approved method before ordinary repair material is placed.
Leak-stopping materials, injection products, drainage systems, waterstops, and crack treatments perform different functions. The contractor should not select one solely because it hardens quickly. The repair must be appropriate for the water pressure, movement, exposure, and final lining system.
Inspect the Repair Before Coating
The repair should be accepted as a separate phase of work before coating preparation begins. Inspection may include:
- Visual examination for cracks, voids, segregation, shrinkage, or incomplete filling
- Sounding for delamination or hollow areas
- Verification of dimensions, thickness, slopes, coves, edges, and transitions
- Confirmation that specified curing has been completed
- Moisture testing when required by the lining manufacturer
- Surface-profile and cleanliness verification after final preparation
- Pull-off adhesion or other testing when specified
- Written acceptance of the repaired substrate
Common Repair Errors
- Repairing only the visible spall while leaving surrounding delamination
- Stopping removal before sound concrete is reached
- Leaving feathered repair edges
- Failing to clean behind exposed reinforcing steel when required
- Adding excess water to improve workability
- Placing outside the product’s temperature, thickness, or working-time limits
- Using a repair material without confirming lining compatibility
- Ignoring active water intrusion or joint movement
- Coating before the repair has cured or reached the permitted moisture condition
- Failing to document changed conditions and additional quantities
Contractor’s Field Checklist
- Has the deterioration mechanism been identified?
- Are structural repairs supported by approved repair documents?
- Are demolition limits, sequencing, and stopping conditions defined?
- Has all unsound concrete been removed?
- Has exposed reinforcement been evaluated and treated as specified?
- Is the repair substrate clean, sound, and properly conditioned?
- Is the repair material suitable for the exposure and final lining?
- Were mixing, placement, thickness, and curing requirements documented?
- Has the required geometry and surface finish been restored?
- Has the completed repair been inspected and accepted before coating?
Knowledge Check
1. Why can a well-adhered lining still fail over deteriorated concrete?
The lining may remain bonded to a weak surface layer while that layer separates from the concrete beneath it. The failure occurs within the substrate rather than at the coating interface.
2. Why should repair material not be selected only by compressive strength?
Successful repair also depends on bond, shrinkage, modulus, placement thickness, moisture condition, chemical exposure, application orientation, curing, and compatibility with the existing concrete and lining system.
3. When should the repaired concrete be inspected?
It should be inspected and accepted as a separate phase after placement and curing, but before final surface preparation and coating application begin.
Technical References and Further Study
-
ACI CODE-562-25, Assessment, Repair, and Rehabilitation of Existing Concrete Structures—Code Requirements and Commentary. This code provides minimum requirements for assessing existing concrete and designing appropriate repair and rehabilitation work.
-
ACI PRC-546-23, Concrete Repair—Guide. This guide provides recommendations for selecting and applying materials and methods used to repair, protect, and strengthen concrete structures.
-
ACI PRC-546.3-23, Materials Selection for Concrete Repair—Guide. This document addresses selection of repair materials for common and special service environments.
-
ICRI Guideline No. 310.2R-2013, Selecting and Specifying Concrete Surface Preparation for Sealers, Coatings, Polymer Overlays, and Concrete Repair. This guideline describes preparation methods and concrete surface-profile benchmarks.
-
ICRI Guideline No. 320.1R-2019, Guide for Selecting Application Methods for the Repair of Concrete Surfaces.
-
ICRI Guideline No. 320.2R-2018, Guide for Selecting and Specifying Materials for Repair of Concrete Surfaces.
-
AMPP SSPC-SP 13/NACE No. 6-2024, Surface Preparation of Concrete. This standard addresses concrete cleanliness, strength, profile, and condition before application of bonded protective coating and lining systems.
-
The repair-material and coating manufacturers’ current technical data sheets, safety data sheets, installation instructions, compatibility requirements, and written project recommendations.
Standards, codes, specifications, and manufacturer instructions may be revised. Confirm the current edition and all project-specific requirements before beginning repair work.
Professional responsibility:
This article provides foundational education. It does not authorize a coating contractor to design structural repairs or replace the judgment of a licensed design professional. Follow the approved repair documents, project specification, applicable codes, current manufacturer instructions, and facility safety requirements. Stop work and obtain written direction when deterioration differs from the documented conditions.
Copyright © 2026 Azimuth Spray Systems, LLC. All Rights Reserved.
No part of this material may be reproduced, copied, distributed, republished, transmitted, stored, or used in any form or by any means without prior written permission from Azimuth Spray Systems, LLC, except for brief quotations used with proper attribution.
AirSprayTech.com - The Finishing Authority®